Add to Favorites
Share

Multicore IEC 60502 0.6/1KV XLPE Insulated LSZH Bedded Galvanised Steel Wire Armoured LSZH Sheathed Cable

  • Description
Product Detail

    CU/XLPE/LSZH/SWA/LSZH (Multi - Cores)

    XLPE Insulated, LSZH Bedded, Galvanised Steel Wire Armoured, LSZH Sheathed Cable


    Application

    These power cable for fixed installations such as distribution networks or industrial installations.

    Such as Plant engineering; Industrial machinery; Heating and air-conditioning systems; Power stations; Stage applications etc.

    Armoured cable suitable for direct burial.

    multi-core - insulation - sheath - swa - sheath.jpg

    Construction

    Conductor: Plain annealed copper, class1 solid or class 2 stranded acc. to IEC 60228.

    Flexible class 5 or tinned conductor could be offer upon request.

    Insulation: Cross-linked polyethlene (XLPE) compound as per IEC 60502-1.

    Insulation Color Code

    Number of Cores Color Code to IEC 60502-1Color Code to BS 5467
    6 and above

    White with Black Numbering

    or Others

    White with Black Numbering

    or Others

    Assembly: Cores cabled together with PP filler and covered with non-woven tape.

    Bedding: Low smoke zero halogen (LSZH) compound type ST8 (90°C) of IEC 60502-1.

    Bedding Colour: Black or other color as per customer request.

    Armour: Galvanized steel wire armoured (SWA).

    Outer Sheath: Low smoke zero halogen (LSZH) compound type ST8 (90°C) of IEC 60502-1.

    Outer Sheath Color: Black or other color as per customer request.

    Electrical Characteristics

    Recommended rated voltages U 

    Highest system voltage

    (U m ) (kV)

    Rated voltage (U 0 ) (kV)
    Categories A and B Category C
    1.20.60.6

    Routine test voltages

    Rated voltage U 0 (kV) 0.6
    Test voltage (kV) 3.5

    Maximum conductor temperatures for different types of insulating compound

    Maximum conductor temperature (°C)
    Normal operationShort-circuit (5 s maximum duration)
    90250

    Operating Temperature: -15°C to 90°C

    Test Voltage: 3.5 kV for 5 minutes


    Reference Standards

    Design Specification: BS6724

    Conductor: IEC60228, BS EN60228

    Flame Retardancy: IEC60332-3-22, BS EN60332-3-22

    Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN50267-2-1, BS EN50267-2-2


    Installation Reference

    Min.Bending Radius (mm): 8 x cable overall diameter

    Max.Pulling Tension (N/mm 2 ): 70


    Dimension

    No of CoresNominal Conductor Area(mm2)

    No .and Diameter of Wires

     (no./mm)

    Thickness of Insulation

    (mm)

    Thickness of Bedding

    (mm)

    Diameter 

    Under 

    Armour

    (mm)

    Diameter 

    of Armour

    Wire

    (mm)

    Thickness of Sheath

    (mm)

    Overall Diameter 

    (mm)

    Approxlmate

    Weight 

    (kg /km)

    51.57/0.530.6110.11.251.816.2573
    77/0.530.61111.251.817.1652
    107/0.530.61141.251.820.1835
    127/0.530.6114.41.251.820.5896
    197/0.530.61171.61.823.81294
    207/0.530.6117.41.61.824.21337
    247/0.530.6119.91.61.826.71541
    377/0.530.6122.91.61.929.91975
    52.57/0.670.7111.21.251.817.3671
    77/0.670.7112.21.251.818.3775
    107/0.670.7115.61.61.822.41145
    127/0.670.7116.21.61.8231233
    197/0.670.7119.11.61.825.91591
    207/0.670.7119.61.61.826.41648
    247/0.670.7122.51.61.829.31911
    377/0.670.71.226.32234.32814
    547/0.850.7112.71.251.818.8812
    77/0.850.7113.91.251.820956
    107/0.850.7117.81.61.824.61413
    127/0.850.7118.41.61.825.21538
    197/0.850.7121.81.61.828.62035
    207/0.850.7122.41.61.829.22112
    247/0.850.7125.721.833.32710
    37
    7/0.850.71.230.121.837.73609